Conferences related to Substation protection

Back to Top

2020 IEEE International Symposium on Electromagnetic Compatibility & Signal/Power Integrity (EMCSI)

This symposium pertains to the field of electromagnetic compatibility.


2020 IEEE Power & Energy Society General Meeting (PESGM)

The Annual IEEE PES General Meeting will bring together over 2900 attendees for technical sessions, administrative sessions, super sessions, poster sessions, student programs, awards ceremonies, committee meetings, tutorials and more


2020 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)

Bi-Annual IEEE PES T&D conference. Largest T&D conference in North America.


2019 IEEE 28th International Symposium on Industrial Electronics (ISIE)

The conference will provide a forum for discussions and presentations of advancements inknowledge, new methods and technologies relevant to industrial electronics, along with their applications and future developments.


2019 IEEE Milan PowerTech

PowerTech is the IEEE PES anchor conference in Europe and has been attended by hundreds of delegates from around the world. It will be an international forum with programme for individuals working in industry and academia, to network, exchange ideas, and discuss the results of their research and development work.

  • 2017 IEEE Manchester PowerTech

    this is IEEE PES anchor conference in Europe covering all areas of electrical power engineering

  • 2015 IEEE Eindhoven PowerTech

    This conference will continue the tradition of the PowerTech conferences held in odd years in Athens, Stockholm, Budapest, Porto, Bologna, St. Petersburg, Lausanne, Bucharest, Trondheim and Grenoble.PowerTech is the anchor conference of the IEEE Power Engineering Society in Europe. It is intended to provide a forum, in the European geographical area, for scientists and engineers interested in electric power engineering to exchange ideas, results of their scientific work, to learn from each other as well as to establish new friendships and rekindle existing ones. Student participation in Power Tech provides an important ingredient toward the event’s success: a special award, the Basil Papadias Award, is presented to the author of the best student paper at each edition. The Power Engineering Society of IEEE organized similar conferences in other parts of the world, such as PowerCon, in the Asia-Pacific region.

  • 2013 IEEE Grenoble PowerTech

    PowerTech is the anchor conference of the IEEE Power & Energy Society in Europe. It is intended to provide a forum for electric power engineering scientists and engineers to share ideas, results of their scientific work, to learn from each other as well as to establish new friendships and maintain existing ones.

  • 2011 IEEE Trondheim PowerTech

    PowerTech is the anchor conference of the IEEE Power & Energy Society in Europe. It is intended to provide a forum for electric power engineering scientists and engineers to share ideas, results of their scientific work and to learn from each other.

  • 2009 IEEE Bucharest Power Tech

    PowerTech is the anchor conference of the IEEE-PES in Europe. It is intended to provide a forum for scientists and engineers interested in electric power engineering to share ideas, results of their scientific work, to learn from each other as well as to establish new friendships and rekindle existing ones.

  • 2007 IEEE Power Tech

  • 2005 IEEE Russia Power Tech

  • 2003 Bologna Power Tech


More Conferences

Periodicals related to Substation protection

Back to Top

Applied Superconductivity, IEEE Transactions on

Contains articles on the applications and other relevant technology. Electronic applications include analog and digital circuits employing thin films and active devices such as Josephson junctions. Power applications include magnet design as well asmotors, generators, and power transmission


Electrical Insulation Magazine, IEEE

The magazine covers theory, analysis, design (computer-aided design), and practical implementation of circuits, and the application of circuit theoretic techniques to systems and to signal processing. Content is written for the spectrum of activities from basic scientific theory to industrial applications.


Electromagnetic Compatibility, IEEE Transactions on

EMC standards; measurement technology; undesired sources; cable/grounding; filters/shielding; equipment EMC; systems EMC; antennas and propagation; spectrum utilization; electromagnetic pulses; lightning; radiation hazards; and Walsh functions


Energy Conversion, IEEE Transaction on

Research, development, design, application, construction, installation, and operation of electric power generating facilities (along with their conventional, nuclear, or renewable sources) for the safe, reliable, and economic generation of electrical energy for general industrial, commercial, public, and domestic consumption, and electromechanical energy conversion for the use of electrical energy


Industrial Electronics, IEEE Transactions on

Theory and applications of industrial electronics and control instrumentation science and engineering, including microprocessor control systems, high-power controls, process control, programmable controllers, numerical and program control systems, flow meters, and identification systems.


More Periodicals

Most published Xplore authors for Substation protection

Back to Top

Xplore Articles related to Substation protection

Back to Top

Harmonic Load Losses in HVDC Converter Transformers

IEEE Power Engineering Review, 1991

None


Control Logic for the Changeover of a Spare Transformer Unit at "El Furrial" Substation 400/230/34.5 kV

2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America, 2006

"El Furrial" 400/115 kV substation project extension includes the implementation of a control logic which will allow an automatic autotransformer spare unit changeover in a three single-phase autotransformer bank 400/230/34.5 kV, 450 MVA. In order to develop an automatic control logic for the spare unit changeover in a three single-phase autotransformer bank, CVG EDELCA has made modifications to the control ...


Think Pascal

IEEE Power Engineering Review, 1986

None


Discussion

Transactions of the American Institute of Electrical Engineers, 1930

None


Power quality analysis and corrections

Conference Record Cement Industry Technical Conference, 2005., 2005

The paper discusses the effect of short circuit fault on sensitive loads and methods for reducing the duration of voltage sags, swells or interruptions by improving existing protection methods or adding advanced protection schemes. Requirements for the recording of power quality events in order to understand their effects on the manufacturing process are presented. Combining multiple overcurrent elements in a ...


More Xplore Articles

Educational Resources on Substation protection

Back to Top

IEEE.tv Videos

Recent Research Activities of Applied Superconductivity in China
Evaluation of Circuit Loading: NFPA Fire Protection Research Foundation
Keynote Address and Opening Remarks - IEEE AI & Ethics Summit 2016
2013 IEEE John Von Neumann Medal
Heuristics for Design for Reliability in Electrical and Electronic Products
Flood or Hurricane Protection?: The New Orleans Levee System and Hurricane Katrina
Technology for Health Summit 2017 - Panel II: Managing the data deluge linked to connected technology in health
Challenges of Big Data on a Global Scale: 2017 Brain Fuel President's Chat
Group on Earth Observations(GEOSS): Applications
Abstraction and Modeling of Cyber Security tutorial, Part 1
Exploring the Attrition Gap: Why Do Women Leave the Engineering Field and What Can Be Done To Prevent It? - panel from IEEE WIE Forum USA East 2017
Working Group Reports - ETAP Forum Namibia, Africa 2017
Abstraction and Modeling of Cyber Security tutorial, Part 2
IEEE World Forum on Internet of Things - Milan, Italy - Sara Foresti - Data Security and Privacy in the Internet of Things - Part 2
IEEE Summit on Internet Governance 2014: Panel II - Security vs. Privacy
IEEE World Forum on Internet of Things - Milan, Italy - Sara Foresti - Data Security and Privacy in the Internet of Things - Part 3
Larson Collection interview with Rudolph Peierls
Coordination of NFPA and IEEE Consensus Document Development
Managing Risks of the Future IoT - Kayne McGladrey - VIC Summit 2019
Social Implications: Perils & Promises of AI - IEEE AI & Ethics Summit 2016

IEEE-USA E-Books

  • Harmonic Load Losses in HVDC Converter Transformers

    None

  • Control Logic for the Changeover of a Spare Transformer Unit at "El Furrial" Substation 400/230/34.5 kV

    "El Furrial" 400/115 kV substation project extension includes the implementation of a control logic which will allow an automatic autotransformer spare unit changeover in a three single-phase autotransformer bank 400/230/34.5 kV, 450 MVA. In order to develop an automatic control logic for the spare unit changeover in a three single-phase autotransformer bank, CVG EDELCA has made modifications to the control and protection principles in the "El Furrial" 400/115 kV substation. Through the control logic for a spare unit changeover in a single phase autotransformer bank at "El Furrial" substation, it is foreseen to maintain periodically in operation the four autotransformers units and to obtain a time reduction in maintenance issues and it will improve the flexibility of the electrical system as well as increase quality of service to one of the most important clients in Venezuela, the oil industry

  • Think Pascal

    None

  • Discussion

    None

  • Power quality analysis and corrections

    The paper discusses the effect of short circuit fault on sensitive loads and methods for reducing the duration of voltage sags, swells or interruptions by improving existing protection methods or adding advanced protection schemes. Requirements for the recording of power quality events in order to understand their effects on the manufacturing process are presented. Combining multiple overcurrent elements in a complex overcurrent characteristic, using negative sequence overcurrent protection, distribution bus and breaker failure protection, fuse saving or selective backup tripping schemes are described.

  • Testing of Multifunctional Distance Protection Relays

    Modern distance protection relays are complex multifunctional devices based on classical or advanced operating principles that impose special requirements for their testing. The paper analyzes the functionality, the functional hierarchy and the schemes typically available in distance relays. It then discusses the methodology for testing of such relays. Testing of individual protection and non-protection elements, complex protection functions and communications based transmission line protection schemes is described in detail.

  • Risk determination in respect to sufficient protection against lightning overvoltages

    Proper rating and placing of surge arresters in HV substations is vital for safe protection of the equipment and high availability of the entire power transmission system. However, a substation is a complex system for steep surges, and for many configurations it cannot be said easily whether all parts of the substation are protected sufficiently by the surge arresters installed or not. Computer simulation of lightning surges and their magnitudes inside a substation can help determining the risk of damages of equipment by lightning overvoltages and supports optimized placing and rating of surge arresters. This paper describes typical problems out of the daily practice. It shows the complexity of insulation co-ordination problems with the need for an individual consideration of each substation. Computer based simulations can show the maximum overvoltage stresses at different locations of a substation for different switching conditions and surge arresters provided already in the planning stage. Representative modeling of transient overvoltages will be shown as well as the general way how to carry out such studies. Main input parameters and influencing factors will be discussed showing possible variations to design the transmission system which would reduce overvoltage stresses. Considering the statistical nature of lightning surges helps to define the failure risk at reasonable amount and optimization of the protection devices necessary.

  • Transient analysis of auxiliary DC installations in power plants and substations

    The goal of this work is to present a developed adequate model that will allow analyzing, dimensioning and control of auxiliary DC installations in power plants, first of all from the protection device point of view. This paper deals with risk of power system blackout caused by auxiliary DC installation failure. In the past, failure of auxiliary DC installation has been caused by wrong selectivity of protection devices. However correct selectivity calculation is based on short-circuit current calculation. For this reasons it has to be made a general mathematical model of auxiliary DC installations in power plants and substations that correspond with laboratory results of short- circuit current test. It was concluded that the transient state during short circuit has to be taken into account and mathematical model of auxiliary DC installations in power plants and substations should include not only resistances, but inductances and capacities of auxiliary DC elements as well as the active network in front of the rectifier. The essence of this work is to suggest changing of present IEC standard 61660 - "short circuit currents in DC auxiliary installations in power plants and substations" that does not correspond with present technology used in auxiliary DC installations. Based on that hypothesis an original program package was developed and used for analyzing and dimensioning auxiliary DC installations in power system. The results obtained by means of the program package are relevant for dimensioning all elements of auxiliary DC installations, particularly when protection devices are considered.

  • Application of autonomous decentralized system in the automatic system of traction substation

    The theory of ADS (Autonomous Decentralized system) has been applied in an automatic system of traction substation. Because of its characteristics of autonomy and decentralization, the control unit and the protection unit must be designed to run in the same environment of both hardware and software and CAN bus must also be taken as communication network. The division of data field is based on the mutuality of facilities. All the units except the local management unit and the communication unit, can be reconfigured so function of these units can be altered easily. The local management unit configures new units when the system is to be expanded. Three communication mode, point-to- point, multicast, broadcast communication mode is used.

  • Electromagnetic Transient Study in the Signaling System of the Towers of the Orinoco River Crossing

    This paper presents the study of the behavior of the system used to feed the warning lights of the 400 kV overhead lines towers that cross the Orinoco River. The feeding of this system is through an isolated ground wire in the section of the crossing. An analysis of the performance of the Balizaje substation is presented from the point of view of their behavior when switching overvoltages appears, with the purpose of evaluating quantitatively some conditions that could be risky for the integrity of the equipment and to obtain data for the adjustment of the substation protection system. This study was made by means of the electromagnetic transient program ATP and it is demonstrated that the Balizaje substation allows to control and to stabilize the voltage levels, guaranteeing the normal operation of the system during different fault and switching scenarios that could appear in the electrical system



Standards related to Substation protection

Back to Top

Guide to Specifications for Gas-Insulated, Electric Power Substation Equipment

This guide covers the technical requirements for the design, fabrication, testing, installation, and in-service performance of gas-insulated substations(GIS). In line with the user functional one-line diagram, the supplier should furnish all components of the GIS such as circuit breakers(CB), disconnect switches(DS), maintenance ground switches (MGS), fast-acting ground switches(FGS), voltage transformers(VT), current transformers(CT), SF6-to-air bushings, SF6-to-cable terminations, surge arresters, all the ...


IEEE Standard Environmental and Testing Requirements for Communications Networking Devices Installed in Electric Power Substations

This document specifies standard service conditions, standard ratings, environmental performance requirements, and testing requirements for communications networking devices and communications ports in protective relays installed in electric power substations. It does not cover such equipment designed for operation in other environments, such as office locations. Other than their communications ports, it does not cover such equipment used in protective relaying ...



Jobs related to Substation protection

Back to Top