Conferences related to Insulation life

Back to Top

2020 IEEE International Power Modulator and High Voltage Conference (IPMHVC)

This conference provides an exchange of technical topics in the fields of Solid State Modulators and Switches, Breakdown and Insulation, Compact Pulsed Power Systems, High Voltage Design, High Power Microwaves, Biological Applications, Analytical Methods and Modeling, and Accelerators.


2020 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)

Bi-Annual IEEE PES T&D conference. Largest T&D conference in North America.


2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)

All areas of ionizing radiation detection - detectors, signal processing, analysis of results, PET development, PET results, medical imaging using ionizing radiation


2020 59th IEEE Conference on Decision and Control (CDC)

The CDC is the premier conference dedicated to the advancement of the theory and practice of systems and control. The CDC annually brings together an international community of researchers and practitioners in the field of automatic control to discuss new research results, perspectives on future developments, and innovative applications relevant to decision making, automatic control, and related areas.


2019 IEEE Electrical Insulation Conference (EIC)

Electrical Materials, Equipment, Testing, Nanotechnologies, Power Systems, Motors, Generators, Transformers, Switchgear



Periodicals related to Insulation life

Back to Top

Applied Superconductivity, IEEE Transactions on

Contains articles on the applications and other relevant technology. Electronic applications include analog and digital circuits employing thin films and active devices such as Josephson junctions. Power applications include magnet design as well asmotors, generators, and power transmission


Broadcasting, IEEE Transactions on

Broadcast technology, including devices, equipment, techniques, and systems related to broadcast technology, including the production, distribution, transmission, and propagation aspects.


Dielectrics and Electrical Insulation, IEEE Transactions on

Electrical insulation common to the design and construction of components and equipment for use in electric and electronic circuits and distribution systems at all frequencies.


Electrical Insulation Magazine, IEEE

The magazine covers theory, analysis, design (computer-aided design), and practical implementation of circuits, and the application of circuit theoretic techniques to systems and to signal processing. Content is written for the spectrum of activities from basic scientific theory to industrial applications.


Energy Conversion, IEEE Transaction on

Research, development, design, application, construction, installation, and operation of electric power generating facilities (along with their conventional, nuclear, or renewable sources) for the safe, reliable, and economic generation of electrical energy for general industrial, commercial, public, and domestic consumption, and electromechanical energy conversion for the use of electrical energy



Most published Xplore authors for Insulation life

Back to Top

Xplore Articles related to Insulation life

Back to Top

Editorial: Condition monitoring and diagnostics

IEEE Transactions on Dielectrics and Electrical Insulation, 2016

This special issue of the IEEE Transactions on Dielectrics and Electrical Insulation (TDEI) is devoted to Condition Monitoring and Diagnostics (CMD) of high voltage insulation systems, with special focus on highlights in research and engineering. Clear trend towards widespread and global diagnostics of insulation systems of power equipment becomes a fact, driven by multi-stress operational conditions including more and more ...


Predetermination of cable deterioration

Electrical Engineering, 1931

IN abstracting his report “The Predetermination of the Deterioration of Impregnated Paper Insulation,” D. W. Roper, Commonwealth Edison Company, Chicago, says:


Study on the insulation life models of power transformer

2008 World Automation Congress, 2008

Insulation is deteriorated gradually and leads to failure because itpsilas often exposed in the electric field, moisture, high temperature, mechanical stress and so on. Lifetime models study of electrical insulation is always a hot topic studied by researchers all over the world. In this paper, firstly, we reviewed some of the insulation life models used currently. And then an electrical-thermal ...


Track-circuit signaling on electrified roads

Proceedings of the American Institute of Electrical Engineers, 1907

Railroads signals may be divided into three general classes according to their functions: (a) Those which confer rights on trains, or restrict their rights, known as train-order signals; (b) Those which designate the route a train is to take, and insure the safe condition of all switches and opposing signals on such route known as interlocking signals; (c) Those which ...


Conductor rail measurements

Proceedings of the American Institute of Electrical Engineers, 1908

General. The Underground Electric Railways Company of London, Ltd., control and operate electrically the Metropolitan District Railway and contingent lines, 56 miles of main-line double track, and three deep level “tube” railways, with connections, aggregating approximately 28 miles of double track. A detailed description of the electrification of the system, by the writer, appeared in the Street Railway Journal of ...



Educational Resources on Insulation life

Back to Top

IEEE-USA E-Books

  • Editorial: Condition monitoring and diagnostics

    This special issue of the IEEE Transactions on Dielectrics and Electrical Insulation (TDEI) is devoted to Condition Monitoring and Diagnostics (CMD) of high voltage insulation systems, with special focus on highlights in research and engineering. Clear trend towards widespread and global diagnostics of insulation systems of power equipment becomes a fact, driven by multi-stress operational conditions including more and more power electronics based switching devices, and the strive for higher transmission capacity. Permanently requirements with respect to safety and reliability in electric power and industrial networks as well as their environmental impacts have highest priorities.

  • Predetermination of cable deterioration

    IN abstracting his report “The Predetermination of the Deterioration of Impregnated Paper Insulation,” D. W. Roper, Commonwealth Edison Company, Chicago, says:

  • Study on the insulation life models of power transformer

    Insulation is deteriorated gradually and leads to failure because itpsilas often exposed in the electric field, moisture, high temperature, mechanical stress and so on. Lifetime models study of electrical insulation is always a hot topic studied by researchers all over the world. In this paper, firstly, we reviewed some of the insulation life models used currently. And then an electrical-thermal aging test is used in oil-paper, the Weibull distribution is used to lifetime statistic. Several models were used to fit test data and calculate the lifetime, finally, the fittest life model was found after analyzing and comparing thee oil-paper insulation models.

  • Track-circuit signaling on electrified roads

    Railroads signals may be divided into three general classes according to their functions: (a) Those which confer rights on trains, or restrict their rights, known as train-order signals; (b) Those which designate the route a train is to take, and insure the safe condition of all switches and opposing signals on such route known as interlocking signals; (c) Those which are used primarily for properly spacing trains, known as block signals.

  • Conductor rail measurements

    General. The Underground Electric Railways Company of London, Ltd., control and operate electrically the Metropolitan District Railway and contingent lines, 56 miles of main-line double track, and three deep level “tube” railways, with connections, aggregating approximately 28 miles of double track. A detailed description of the electrification of the system, by the writer, appeared in the Street Railway Journal of March 4, 1905.

  • End Component of Armature Leakage Reactance of Round-Rotor Generators

    None

  • Investigation the effect of environmental factors on the performance of polymeric outdoor insulation

    Surface tracking is one of the severe degradation mechanisms observed on polymeric insulators. There are too many factors associated with the degradation process, hence it is not easy to make an estimate about the useful service life of an insulator. However it is possible to reduce the variability observed in the tracking initiation times and tracking patterns by testing the samples in laboratory under predefined conditions (4 kV applied voltage and 36 ml/h flow rate of liquid). In this study, by using the ASTM D 2303 Inclined Plane Tracking Test method the effects of longitudinal compressive and tensile stress, ultraviolet (UV) radiation and wind pressure from different positions with respect to the surface of the sample under test have been investigated in detail. All samples have been prepared by using polyester resin without any accelerator. In all cases tracking initiation times were reduced significantly depending on the external conditions. UV radiation and wind pressure caused bushy type carbonised tracking patterns with wide branches around the high voltage electrode.

  • Discussion on “transmission line crossings of railroad rights-of-way” San Francisco, Cal., May 6, 1910. (see proceedings for June, 1910)

    None

  • Discussion on “the New Haven system of single-phase distribution, with special reference to sectionalization”, at New York, January 10, 1908

    None

  • Selection and design of the electrification of the San Francisco-Oakland Bay Bridge railway

    THE San Francisco-Oakland Bay Bridge was built by the State of California not only for heavy automobile traffic but also to benefit the 30,000,000 suburban railway passengers per year who are now transported across San Francisco Bay by passenger ferry boats belonging to the railway companies. The railway passengers, who are practically all commuters living in the east-bay cities and working in San Francisco, board the electric trains on branch lines near their homes and are taken to the piers by rail. They then transfer to the ferry boats which require about 20 minutes to cross the bay to the ferry building in San Francisco where the passengers disembark and walk or take street cars to their places of business. When the Bridge Railway is completed, passengers will board the electric trains near their homes in the east-bay cities and will be transported by rail, without transfer, to the new railway terminal in San Francisco near the business district of the city.



Standards related to Insulation life

Back to Top

Guide for Loading Liquid Immersed Transformers and Voltage Regulators

This guide provides recommendations for loading mineral-oil-immersed transformers and voltage regulators with insulation systems rated for a 65°C average winding temperature rise at rated load. This guide applies to transformers manufactured in accordance with IEEE C57.12.00 and tested in accordance with IEEE C57.12.90, and voltage regulators manufactured and tested in accordance with C57.15. Because a substantial population of transformers and ...


Guide to Specifications for Gas-Insulated, Electric Power Substation Equipment

This guide covers the technical requirements for the design, fabrication, testing, installation, and in-service performance of gas-insulated substations(GIS). In line with the user functional one-line diagram, the supplier should furnish all components of the GIS such as circuit breakers(CB), disconnect switches(DS), maintenance ground switches (MGS), fast-acting ground switches(FGS), voltage transformers(VT), current transformers(CT), SF6-to-air bushings, SF6-to-cable terminations, surge arresters, all the ...


IEEE Guide for Evaluation and reconditioning of Liquid Immersed Power Transformers

This guide includes guidelines for the following: insulating oil maintenance and diagnostics, oil reclamation, testing methods for the determination of remaining insulation (paper) life, and upgrades of auxiliary equipment such as bushings, gauges, deenergized tap changers (DETCs), load tap changers (LTCs) (where applicable), and coil reclamping. The goal of this guide is to assist the user in extending the useful ...


IEEE Recommended Practice for Electric Power Systems in Commercial Buildings