Conferences related to Shielded Power Cable Systems

Back to Top

2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)

The Conference focuses on all aspects of instrumentation and measurement science andtechnology research development and applications. The list of program topics includes but isnot limited to: Measurement Science & Education, Measurement Systems, Measurement DataAcquisition, Measurements of Physical Quantities, and Measurement Applications.


2020 IEEE International Symposium on Electromagnetic Compatibility & Signal/Power Integrity (EMCSI)

This symposium pertains to the field of electromagnetic compatibility.


2020 IEEE Power & Energy Society General Meeting (PESGM)

The Annual IEEE PES General Meeting will bring together over 2900 attendees for technical sessions, administrative sessions, super sessions, poster sessions, student programs, awards ceremonies, committee meetings, tutorials and more


2020 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)

Bi-Annual IEEE PES T&D conference. Largest T&D conference in North America.


IECON 2020 - 46th Annual Conference of the IEEE Industrial Electronics Society

IECON is focusing on industrial and manufacturing theory and applications of electronics, controls, communications, instrumentation and computational intelligence.


More Conferences

Periodicals related to Shielded Power Cable Systems

Back to Top

Aerospace and Electronic Systems Magazine, IEEE

The IEEE Aerospace and Electronic Systems Magazine publishes articles concerned with the various aspects of systems for space, air, ocean, or ground environments.


Applied Superconductivity, IEEE Transactions on

Contains articles on the applications and other relevant technology. Electronic applications include analog and digital circuits employing thin films and active devices such as Josephson junctions. Power applications include magnet design as well asmotors, generators, and power transmission


Communications, IEEE Transactions on

Telephone, telegraphy, facsimile, and point-to-point television, by electromagnetic propagation, including radio; wire; aerial, underground, coaxial, and submarine cables; waveguides, communication satellites, and lasers; in marine, aeronautical, space and fixed station services; repeaters, radio relaying, signal storage, and regeneration; telecommunication error detection and correction; multiplexing and carrier techniques; communication switching systems; data communications; and communication theory. In addition to the above, ...


Dielectrics and Electrical Insulation, IEEE Transactions on

Electrical insulation common to the design and construction of components and equipment for use in electric and electronic circuits and distribution systems at all frequencies.


Electrical and Computer Engineering, Canadian Journal of

The Canadian Journal of Electrical and Computer Engineering, issued quarterly, has been publishing high-quality refereed scientific papers in all areas of electrical and computer engineering since 1976. Sponsored by IEEE Canada (The Institute of Electrical and Electronics Engineers, Inc., Canada) as a part of its role to provide scientific and professional activity for its members in Canada, the CJECE complements ...


More Periodicals

Most published Xplore authors for Shielded Power Cable Systems

Back to Top

No authors for "Shielded Power Cable Systems"


Xplore Articles related to Shielded Power Cable Systems

Back to Top

IEEE Draft Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF) (less than 1 Hz)

IEEE P400.2/D13 August 2012, 2012

This guide describes very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems. Whenever possible, cable systems are treated in a similar manner to individual cables. Tables are included as an aid to identifying the effectiveness of the VLF ac voltage test for various cable ...


IEEE Draft Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF) (less than 1 Hz)

IEEE P400.2/D12 January 2012, 2012

This guide describes very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems. Whenever possible, cable systems are treated in a similar manner to individual cables. Tables are included as an aid to identifying the effectiveness of the VLF ac voltage test for various cable ...


IEEE Guide for Field Testing of Laminated Dielectric, Shielded Power Cable Systems Rated 5 kV and Above with High Direct Current Voltage

IEEE Std 400.1-2007 (Revision of IEEE Std 400.1-1991), 2007

The recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, laminated dielectric insulated power cable systems rated 5 kV and above are presented in this guide. It applies to all types of laminated power cable systems such as paper insulated, lead covered, pipe-type, and pressurized cables that are intended for the transmission or distribution of electric ...


IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz) - Redline

IEEE Std 400.2-2013 - Redline, 2013

Very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems are described in this guide. Whenever possible, cable systems are treated in a similar manner to individual cables. Tables are included as an aid to identifying the effectiveness of the VLF ac voltage test for ...


IEEE Draft Guide for Field-Testing of Shielded Power Cable Systems Rated 5kV and Above with Damped Alternating Current Voltage (DAC)

IEEE P400.4/D9, June 2015, 2015

In this guide is the application of Damped AC (DAC) for field testing 1 of power cables isdescribed. DAC voltage withstand testing and diagnostic tests and measurements that areperformed in combination with DAC voltage application in the field on shielded power cablesystems are discussed. Whenever possible, cable systems are treated in a similar manner toindividual cables. Tables and figures are ...


More Xplore Articles

Educational Resources on Shielded Power Cable Systems

Back to Top

IEEE-USA E-Books

  • IEEE Draft Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF) (less than 1 Hz)

    This guide describes very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems. Whenever possible, cable systems are treated in a similar manner to individual cables. Tables are included as an aid to identifying the effectiveness of the VLF ac voltage test for various cable system insulation problems.

  • IEEE Draft Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF) (less than 1 Hz)

    This guide describes very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems. Whenever possible, cable systems are treated in a similar manner to individual cables. Tables are included as an aid to identifying the effectiveness of the VLF ac voltage test for various cable system insulation problems.

  • IEEE Guide for Field Testing of Laminated Dielectric, Shielded Power Cable Systems Rated 5 kV and Above with High Direct Current Voltage

    The recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, laminated dielectric insulated power cable systems rated 5 kV and above are presented in this guide. It applies to all types of laminated power cable systems such as paper insulated, lead covered, pipe-type, and pressurized cables that are intended for the transmission or distribution of electric power. The tabulated test levels assume that the cable systems have an effectively grounded neutral system or a grounded metallic shield.

  • IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz) - Redline

    Very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems are described in this guide. Whenever possible, cable systems are treated in a similar manner to individual cables. Tables are included as an aid to identifying the effectiveness of the VLF ac voltage test for various cable system insulation problems.

  • IEEE Draft Guide for Field-Testing of Shielded Power Cable Systems Rated 5kV and Above with Damped Alternating Current Voltage (DAC)

    In this guide is the application of Damped AC (DAC) for field testing 1 of power cables isdescribed. DAC voltage withstand testing and diagnostic tests and measurements that areperformed in combination with DAC voltage application in the field on shielded power cablesystems are discussed. Whenever possible, cable systems are treated in a similar manner toindividual cables. Tables and figures are included to show the effectiveness of the DAC acvoltage test, the diagnostic evaluation and the user experiences in the past years for field testing of different medium and (extra) high voltage cable system.

  • IEEE Draft Guide for Field-Testing of Shielded Power Cable Systems Rated 5kV and Above with Damped Alternating Current Voltage (DAC)

    In this guide is the application of Damped AC (DAC) for field testing 1 of power cables isdescribed. DAC voltage withstand testing and diagnostic tests and measurements that areperformed in combination with DAC voltage application in the field on shielded power cablesystems are discussed. Whenever possible, cable systems are treated in a similar manner toindividual cables. Tables and figures are included to show the effectiveness of the DAC acvoltage test, the diagnostic evaluation and the user experiences in the past years for field testing of different medium and (extra) high voltage cable system.

  • IEEE Approved Draft Guide for Field-Testing of Shielded Power Cable Systems Rated 5kV and Above with Damped Alternating Current Voltage (DAC)

    In this guide is the application of Damped AC (DAC) for field testing 1 of power cables isdescribed. DAC voltage withstand testing and diagnostic tests and measurements that areperformed in combination with DAC voltage application in the field on shielded power cablesystems are discussed. Whenever possible, cable systems are treated in a similar manner toindividual cables. Tables and figures are included to show the effectiveness of the DAC acvoltage test, the diagnostic evaluation and the user experiences in the past years for field testing of different medium and (extra) high voltage cable system.

  • IEEE Draft Guide for Fault Locating Techniques on Shielded Power Cable Systems

    Test and measurements, which are performed on shielded power cables to identify the location of a fault, are described. Whenever possible, the limitations of a particular test and measurement to locate a fault are provided and recommendations are made regarding specialized fault locating techniques. A fault characterization chart is included as an aid to select a fault locating technique.

  • IEEE Approved Draft Guide for Fault Locating Techniques on Shielded Power Cable Systems

    Test and measurements, which are performed on shielded power cables to identify the location of a fault, are described. Whenever possible, the limitations of a particular test and measurement to locate a fault are provided and recommendations are made regarding specialized fault locating techniques. A fault characterization chart is included as an aid to select a fault locating technique.

  • IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz)

    Very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems are described in this guide. Whenever possible, cable systems are treated in a similar manner to individual cables. Tables are included as an aid to identifying the effectiveness of the VLF ac voltage test for various cable system insulation problems.



Standards related to Shielded Power Cable Systems

Back to Top

Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems

This Guide lists the various field test methods that are presently available or under development to perform field tests on insulated, shielded power cable systems rated 5 kV through 500 kV. A summary of advantages and disadvantages of the methods will be included. Users should avail themselves of th technical papers that are included as References and in the Bibliography ...


IEEE Guide for Fault Locating Techniques on Shielded Power Cable Systems

This document will be a guide for cable fault locating techniques on shielded power cable systems. This guide will be applicable to all insulated, shielded power cable systems.


IEEE Guide for Field Testing of Laminated Dielectric, Shielded Power Cable Systems Rated 5 kV and Above with High Direct Current Voltage

This guide presents the recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, laminated dielectric insulated power cable systems rated 5 kV and above. It applies to all types of laminated power cable systems such as paper-insulated lead covered, pipe-type, and pressurized cables that are intended for the transmission or distribution of electric power. The tabulated ...


IEEE Guide for Field Testing of Laminated Dielectric, Shielded Power Cable Systems Rated 5 kV and Above with High Direct Current Voltage

This guide presents the recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, laminated dielectric insulated power cable systems rated 5 kV and above. It applies to all types of laminated power cable systems such as paper-insulated lead covered, pipe-type, and pressurized cables that are intended for the transmission or distribution of electric power. The tabulated ...


IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)

This guide describes very low frequency (VLF) withstand and diagnostic tests and the measurements that are performed in the field on service-aged shielded medium voltage cables with extruded and laminated dielectric insulation. VLF test methods utilize ac signals at frequencies less than 1 Hz. The most commonly used, commerically available, VLF test frequency is 0.1 Hz. Whenever possible, cable systems ...


More Standards

Jobs related to Shielded Power Cable Systems

Back to Top