Cable Terminations

View this topic in


Conferences related to Cable Terminations

Back to Top

2012 IEEE International Conference on Condition Monitoring and Diagnosis (CMD)

Visit website

Condition monitoring and diagnosis for power equipments and power systems\,power plants\, dielectric materials and their aging mechanisms\, degradation assessment for power system\, application of information and communication technologies for condition monitoring and diagnosis\, tropical climate and other related issues including recycling\, reuse and mitigation\,strategic planning and management for condition monitoring and diagnosis.

  • 2008 International Conference on Condition Monitoring and Diagnosis (CMD)

    Condition Monitoring and Diagnosis for Power Plants Condition Monitoring and Diagnosis of HV Power Apparatus and Power System Electrical, Mechanical, Thermal and Chemical Failure Phenomena Dielectric Materials Aging and Failure Mechanism Advanced Sensing Technologies for Condition Monitoring and Diagnosis Application of Artificial Intelligence for Data Mining and Condition Assessment Applications of Information Technology for Asset Management Strategic Planning and Management for Condition Monitoring



Xplore Articles related to Cable Terminations

Back to Top
  • A new era in cable designs and materials to resolve environmental issues

    Barras, R.E.; Snow, Joseph H.; Bow, Kenneth E.; Voltz, D.A. Petroleum and Chemical Industry Conference, 1996, Record of Conference Papers. The Institute of Electrical and Electronics Engineers Incorporated Industry Applications Society 43rd Annual, 1996

    Environmental issues have had a profound influence on cable designs and materials used in cable construction. This paper addresses the issues concerned with the effects of cable on the environment, as well as the effects of environmental conditions on cable performance and reliability. Effects on the environment include release of toxic materials and contamination of ground water. Environmental effects on ...

  • The application of on-line PDM on in-service MV cable terminations

    Min-Yen Chiu; Chang-Hsing Lee; Chih-Hsien Huang; Shih-Shong Yen Condition Monitoring and Diagnosis, 2008. CMD 2008. International Conference on, 2008

    The majority of cable failures on distribution system is caused by the defects in cable terminations and cable joints. Failure mechanisms reported in cable accessories are predominantly involve partial discharge deterioration caused by voids, contaminants and workmanship problems. Therefore, partial discharge measurement (PDM) is an effective diagnostic preventing cable system failure. However, conventional PDM needs outage and time consumption, and ...

  • Dielectric response of cable accessories and its influence on cable diagnostics

    Amyot, N.; David, E.; Fournier, D.; Jean, D.; Lalancette, D. Electrical Insulation and Dielectric Phenomena, 2002 Annual Report Conference on, 2002

    In this paper, dielectric measurements performed on unaged, field-aged and artificially damaged cable joints are reported. All cable joints, but the unaged, were characterized with respect to their discharge inception and extinction voltages. Various types of unaged indoor and outdoor cable terminations were also analysed. Both time domain (TDS) and frequency domain dielectric spectroscopy (FDS) were performed at various voltage ...

  • Partial discharge measurement in transmission-class cable terminations

    Ahmed, N.; Morel, O.; Srinivas, N. Transmission and Distribution Conference, 1999 IEEE, 1999

    This paper describes on-line and off-line partial discharge (PD) measuring techniques applicable to transmission cable terminations. The on-line technique can be utilized for both extruded and pipe-type cable terminations. In pipe-type cable terminations, the on-line technique is only applicable to newly installed terminations, as it requires an internal inductive sensor. In the case of extruded cable terminations, on-line testing is ...

  • WEB database for the evaluation of PD measurements on MV cable system

    Putter, H.T.; Gotz, D.; Petzold, F.; Bottcher, S. Condition Monitoring and Diagnosis (CMD), 2012 International Conference on, 2012

    The medium voltage (MV) cable network is an important asset of a distribution system. It represents large investment, and it must guarantee a reliable operation and it is from economic point of view essential to extend the life time of the medium voltage power cables as much as possible. It is known that with increasing age, the number of faults ...

More Xplore Articles


Educational Resources on Cable Terminations

Back to Top
  • Fiber Optic Connectors - Termination and Testing

    Johnson, Larry Fiber Optic Connectors - Termination and Testing, 2009

    In this tutorial we will review the methods used to bond, hold and align optical fibers for factory and field terminations. Scribing tools and techniques will also be covered. Next, proper polishing of the optical endface will be reviewed as well as the importance of cleaning optical surfaces to minimize damage, lower attenuation, and improve reflection values. This is followed ...


Standards related to Cable Terminations

Back to Top

Periodicals related to Cable Terminations

Back to Top
  • Applied Superconductivity, IEEE Transactions on

    Contains articles on the applications and other relevant technology. Electronic applications include analog and digital circuits employing thin films and active devices such as Josephson junctions. Power applications include magnet design as well asmotors, generators, and power transmission

  • Power Delivery, IEEE Transactions on

    Research, development, design, application, construction, the installation and operation of apparatus, equipment, structures, materials, and systems for the safe, reliable, and economic delivery and control of electric energy for general industrial, commercial, public, and domestic consumption.


IEEE Organizations related to Cable Terminations

Back to Top